    Explosion Proof Temperature Sensor, -50-80°C/-50-260°C

    SKU: SUCH-TS-CWDZ71C
    $145.98
    ● Range: -50-80°C / -50-260°C ● Output Signal: 4-20mA, 4-20mA Hart, RS485, Pt100 (Optional) ● Accuracy Level: 0.25%FS, 0.5%FS ● Display: LCD Display, No Backlight
    *
    *
    *
    *
    *
    *
    *
    *
    🚚 Free shipping
    🕒 Delivery date: 6-12 days
    🔁 30-day Returns
    Overview

    The explosion proof temperature sensor is designed to deliver accurate and reliable temperature measurements in harsh industrial environments, with a temperature range of -50°C to 80°C or -50°C to 260°C. With high accuracy levels of 0.25%FS or 0.5%FS, this sensor provides precise readings. The SUCH sensor also offers flexibility with multiple probe options and two types of cables, ensuring durability with high temperature, corrosion, and wear resistance. An LCD display is included, though without backlighting.

    Feature

    Explosion proof temperature sensor detail

    • The sensor has multiple explosion-proof features, including intrinsic safety explosion-proof and intrinsic safety dust explosion-proof.
    • Multiple probes are available for selection to meet various on-site working conditions.
    • Two types of cables are available, offering high temperature and corrosion resistance, wear resistance, and increased flexibility.
    • It uses imported PT100 platinum resistance, with 1/3B class high measurement accuracy.
    • The SUCH sensor has a metal housing, which is die-cast for enhanced durability and strength.

    Dimension (Unit:mm)

    Main Body

    Explosion proof temperature sensor body dimension

    Probe

    Explosion proof temperature sensor probe dimension

    Wiring Diagram

    Explosion proof temperature sensor wiring diagram

    Specs
    Measurement Medium Solids / Water / Air (Compatible with Contact Materials)
    Measurement Range -50-80°C, -50-260°C
    Output Signals / Power Supply 4-20mA (15-32VDC), 4-20mA (15-24VDC Intrinsically Safe), 4-20mA Hart (13-32VDC), RS485 (9-32VDC), Pt100 (Output Unpowered)
    Probe Type Threaded Type, Sheathed Type, Ring Lug Type, Magnetic Type, Without Fixed Thread (Optional)
    Accuracy Level
    • 0.5%FS (Default), 0.25%FS (Optional)
    • Meter Head Accuracy 0.05%FS (LCD with Backlight)
    Cable PTFE Shielded Compensation Cable (φ3.2mm Temperature Resistance -200-260℃), Polyurethane Shielded Compensation Cable (φ4.7mm Temperature Resistance -50-100℃) (Customisable)
    Explosion Proof Type Intrinsically Safe Ex ia IIC T6 Ga (Current Output Only), Dust Intrinsically Safe Ex ia IIIC T85°C Da (Current Output Only). Note: Intrinsically Safe Must Be Powered by a Safety Grid or Intrinsically Safe Power Supply.
    Response Time 18s (Compliant with IEC60751, 0.4m/s Airflow, 10°C Step)
    Stability ±0.1% FS/year
    Transmission Time 400ms
    Protection Level Housing: IP65, Probe: IP68 (Note: Protection Level Applies When the Connector Is Fully Connected)
    Weight With Display: Approx. 150g
    Resolution  Analog Output: ±0.02% FS, Digital Output: ±0.1°C
    Housing Material ABS Engineering Plastic
    Cable Locking Head Nylon (Suitable for Cable Diameter 4~6mm)
    Display LCD Display, No Backlight
    Probe Material 304 Stainless Steel
    Seal Material Nitrile Rubber
    Note: Cable length between meter head and probe: 1m (default), other lengths please contact us.

    PDF computingExplosion Proof Temperature Sensor, -50-80°C/-50-260°C User Manual

    Application
    Temperature control in wastewater treatment

    Wastewater Treatment

    Industrial gases

    Industrial Gases

    HVAC

    HVAC

    FAQ

    An explosion-proof temperature sensor is designed to safely operate in hazardous environments where flammable gases, vapors, or dust are present. It is built with special protective features, such as intrinsic safety ratings, to prevent the sensor from igniting or causing sparks that could trigger an explosion. These sensors are typically used in industries such as oil and gas, chemicals, and pharmaceuticals.

    Choosing an explosion-proof temperature sensor is crucial for ensuring safety in environments where explosive gases or combustible dust are present. Using standard temperature sensors in such conditions could lead to serious safety risks, including fire or explosions. Explosion-proof sensors meet stringent safety standards, offering protection against these hazards and ensuring reliable temperature measurement without compromising safety.

    The use of a magnetic probe significantly improves the flexibility of sensor installation by allowing for quick, tool-free mounting on metal surfaces. The embedded magnets securely hold the probe in place, making it easy to attach to pipes, tanks, or other metallic structures without the need for drilling or welding. This feature enables fast installation and repositioning, ideal for applications where flexibility and minimal disruption are essential. Additionally, the magnetic probe is stable enough to remain securely attached even in vibrating environments, ensuring reliable temperature measurements without the need for permanent modifications to the equipment. It is particularly useful for temporary or portable setups, providing versatility in various industrial settings.