Phosphine (PH3) Gas Sensor, RS485/TTL Module Output

SKU: SUCH-GAS-PH3
$198.99
● Detect: Phosphine (PH3) ● Rang: 0-20ppm ● Interface: RS485, TTL ● Resolution: 0.1 ppm
*
🚚 Free shipping
🕒 Delivery date: 6-12 days
🔁 30-day Returns
Overview

This PH3 sensor module is designed specifically for industrial gas detection. It has a detection range of 0-20ppm, a resolution of up to 0.1ppm, an accuracy of ≤±3%, and a repeatability of ≤±1%. It uses natural diffusion sampling to monitor phosphine concentration in real time. The module uses a TTL/RS485 communication interface with a baud rate of 9600, allowing seamless integration with PLCs, controllers, and IoT devices.

Feature

  • This phosphine sensor supports hot plugging and unplugging, is fully temperature compensated, and is factory calibrated.
  • It is ready for use without further calibration and provides TTL/RS485 output.
  • The gas sensor uses standard MODBUS communication protocol for convenient operation.

Dimension (unit: mm)

PH3 gas sensor module dimension

Module Pin Definition

Pin Definition Functional Description (MIN) V (TYP) V (MAX) V
GND Power Ground 0 0 ----
IO1 Analog Signal Measurement 0 2 3
VCC Power 4.5 5 5.5
TX Serial Send 0 3 ----
RX Serial Receive 0 3 ----


Cross Interference

Interference Gas Gas Concentration Used (ppm) Displayed Value (ppm PH₃)
CO 75 0
SO₂ 20 3
H₂S 50 15
H₂ 1000 0.3
NH₃ 40 0
NO 30 0.4
NO₂ 20 -5


Response Recovery Curve

PH3 gas sensor response recovery curve

Baseline Temperature Dependency Curve

PH3 gas sensor baseline temperature dependence curve

Specs
Detecting Gas PH3
Detecting Range 0-20ppm
Working Voltage DC 5V±0.5V
Power Consumption ≤1W
Working Temperature -20°C~50°C
Humidity 15%~95%RH (no condensation)
Working Pressure 86~106Kpa
Adoption Method Natural diffusion
Detection Unit ppm
Resolution 0.1ppm
Technical Principle Electrochemical three electrodes
Tolerance ≤±3%
Repeatability ≤±1%
Response Time ≤60s
Communication Format UART baud rate 9600, data bit: 8; stop bit: 1; check bit: none
Communication Protocol Modbus-RTU communication protocol
Communication Interface TTL, RS485 (optional)
Warm-up Time 30s (user adjustable)
Lifetime 2 years
Weight 10g
Application
PH3 gas sensor of public restrooms

Public Restrooms

PH3 gas sensor of pipeline corridors and tunnels

Pipeline Corridors and Tunnels

PH3 gas sensor of manhole cover

Manhole Covers

FAQ

After amplification and filtering, the PH3 gas sensor signal is processed by a microprocessor and output as a digital signal. Different sensors have different filtering and amplification circuits.

Phosphine sensors are widely used in agricultural grain storage, fertilizer production, semiconductor manufacturing, and environmental safety testing. In grain storage, phosphine is often used as a fumigant, and sensors can monitor concentrations in real time to ensure personnel safety. In the chemical industry, they can help detect potential phosphine leaks in factories, reducing the risk of explosions and poisoning. Sensors can also be used in laboratory research and environmental monitoring to ensure air quality and workplace safety.

To ensure the long-term stability of PH3 sensors, regular maintenance is required. First, calibration should be performed according to manufacturer requirements, typically every 6 to 12 months. Second, the sensor probe must be kept clean to avoid clogging with dust or chemical residue. When not in use, the sensor should be stored in a dry, clean environment to avoid corrosion from high temperatures or highly corrosive gases. If used in high humidity or dusty environments, it is recommended to use a protective cover and filter to extend the service life and ensure accuracy.

0.0 0
Write your own review Close
*
*