Online Turbidity Sensor, 0~200/1000/3000 NTU

SKU: SUCH-TUS-DTS210
$932.92
● Output signal RS485, MODBUS/RTU protocol ● Measuring range 0~200/1000/3000 NTU ● Resolution 0.1 NTU, 0.1℃ ● Operating conditions: 0~50℃, <0.2MPa
*
🚚 Free shipping
🕒 Delivery date: 6-12 days
🔁 30-day Returns
Overview

Online turbidity sensor is based on the principle of light scattering and employs an infrared LED light source and fiber optic transmission path design, exhibiting excellent resistance to external light interference. SUCH turbidity sensor has a built-in temperature compensation module, enabling long-term stable online monitoring in environments ranging from 0~50℃. It supports RS485 (MODBUS/RTU) communication, has an IP68 protection rating, and can be used continuously at water depths up to 20 meters, making it suitable for conventional water turbidity monitoring scenarios.

Feature

  • Digital sensor with direct RS485 output, supporting MODBUS/RTU communication.
  • Based on the light scattering principle with a built-in temperature sensor for automatic temperature compensation.
  • Fiber-optic optical path design provides strong resistance to ambient light interference.
  • Infrared LED light source with additional optical filtering for enhanced anti-interference performance and high measurement stability.
  • Sensor surface treated with anti-corrosion passivation for reliable operation in various water environments.
  • Low-power design with internal circuitry optimized for strong electromagnetic interference resistance.

Turbidity sensor feature

Dimension (Unit: mm)

Online turbidity sensor dimension

Wiring

Wire Type Description
Brown wire Power supply (12VDC)
Black wire Ground (GND)
Blue wire 485A
White wire 485B
Bare wire Shielding layer


Installation

Turbidity sensor installation

Note: Install the sensor in an area with slow-flowing, bubble-free water; keep the sensor 5cm away from the surrounding walls.

Specs
Output Signal RS485, MODBUS/RTU protocol
Measurement Method Light scattering principle
Measuring Range 0~200 NTU or 0~1000 NTU or 3000 NTU
Accuracy ±3% of indicated value or ±3 NTU, whichever is greater (0~200 NTU)
±3% of indicated value or ±5 NTU, whichever is greater (0~1000 NTU)
±3% of indicated value or ±10 NTU, whichever is greater (0~3000 NTU)
±0.5℃
Resolution 0.1 NTU, 0.1℃
Operating Conditions 0~50℃, <0.2MPa
Calibration Method Two-point calibration
Response Time 30 seconds (T90)
Temperature Compensation Automatic temperature compensation
Power Supply 12 or 24VDC±20%, 20mA
Dimensions Φ34*181.5 mm
Protection Rating IP68; water depth 20 meters
Lifespan Sensor life 3 years or more
Cable Length 10 meters (default), customizable
Sensor Housing Material 316L (other)
Application
Agricultural water use

Agricultural Water Use

Pipeline water monitoring

Pipeline Water Monitoring

Environment protection monitoring

Environment Protection Monitoring

FAQ

The sensor uses the light scattering principle with an infrared LED light source to measure turbidity accurately and reliably.

The sensor should be fully immersed in the water to be measured, avoiding air bubbles, sediment accumulation, or strong water flow directly impacting the probe.

Temperature may influence optical measurements, but the built-in temperature sensor provides automatic temperature compensation to ensure stable readings.

0.0 0
Write your own review Close
*
*