Water Turbidity Sensor Probe, 0~50/200 to 4000 NTU

SKU: SUCH-TUS-RSZD
$271.39
● Output signal: RS485 (ModBus-RTU) ● Measurement method: 90° scattered light method ● Measuring range 0~50/200/1000/4000 NTU ● Resolution 0.1 NTU, 0.1℃
*
🚚 Free shipping
🕒 Delivery date: 6-12 days
🔁 30-day Returns
Overview

Water turbidity sensor probe employs the 90° scattering light method and supports RS485 (ModBus-RTU) communication. It enables continuous and accurate monitoring of water turbidity, with selectable measurement ranges of 0~50/200/1000/4000 NTU and a resolution up to 0.1 NTU. SUCH turbidity sensor has a response time of approximately 30 seconds and is suitable for various scenarios including agricultural water use, industrial discharge, mine wastewater, aquaculture, surface water monitoring, and end-of-pipe treatment of domestic sewage. It operates stably in environments ranging from 0~50℃ and <0.6MPa.

Feature

  • Fast response and stable measurement using laser scattering, unaffected by magnetic interference for continuous monitoring.
  • Supports online detection with simultaneous measurement of turbidity and temperature in one device.
  • Fiber-optic structure with a built-in temperature sensor minimizes external light interference, offering high sensitivity and long service life.
  • High protection performance with IP68 rating, allowing use underwater up to 20 meters.
  • Built-in temperature sensor provides automatic temperature compensation to reduce errors and improve accuracy.
  • Equipped with a 3/4 NPT tapered thread for easier installation and secure mounting.

Turbidity sensor probe feature

Dimension (Unit: mm)

Turbidity sensor probe dimension

Detail

Turbidity sensor probe detail

Installation

Turbidity sensor probe installation

Note: Avoid installing the measuring device in areas with strong water flow to minimize the impact of water bubbles on the measurement. Keep the measuring probe 5cm away from the bottom.

Specs
Output Signal RS485, ModBus-RTU Protocol
Measurement Method 90° Scattered Light Method
Measuring Range 0~50/200/1000/4000NTU
Accuracy ±5% of Indicated Value or ±3NTU, whichever is greater (0~1000NTU)
±3% of Indicated Value or ±2NTU, whichever is greater (0~200NTU)
±0.5℃
Resolution 0.1NTU, 0.1℃
Operating Conditions 0~50℃, <0.6MPa
Calibration Method Two-Point Calibration
Response Time 30s T90
Temperature Compensation Automatic Temperature Compensation (Pt1000)
Power Supply 12 or 24VDC main 10%, 10mA
Dimensions Diameter 30mm; Length 166.5mm
Protection Class IP68; Water depth 20m
Lifespan Normal use 2 years
Cable Length 5m: (default), customizable
Sensor Housing Material PVC
Application
Wastewater treatment

Wastewater Treatment

Agricultural water use

Agricultural Water Use

Aquaculture industry

Aquaculture Industry

FAQ

It uses the 90° scattered light method. When a light beam enters the water sample, suspended particles cause the light to scatter. The sensor measures the scattered light intensity at a 90° angle to the incident beam and compares it with internal calibration values. After linear processing, it calculates and outputs the final turbidity value.

1. It is recommended to clean the sensor probe every 30 days to remove any attached substances.

2. Avoid using hard objects during cleaning to prevent scratching the probe’s optical surfaces.

3. Wipe gently with a soft, damp cloth.

It is ideal for agricultural water, industrial wastewater, aquaculture, surface water monitoring, and sewage treatment.

0.0 0
Write your own review Close
*
*