The SUCH air pressure switch monitors pressure and switches an electrical circuit when the preset pressure is reached. It covers preset pressure settings from 0.2 to 65 bar and offers normally open (NO) or normally closed (NC) contacts. With an IP67-rated housing and pressure-dependent temperature ratings, it is suitable for air compressors, refrigeration systems, pumps, and other equipment using air, water, oil, or compatible refrigerants.
Choose a switch that matches the compressor’s cut-in and cut-out pressures, control circuit, and electrical load. Check whether the switch needs to control the motor directly or operate through a contactor or motor starter. Also consider the compressor’s unloading arrangement to help prevent excessive starting current or repeated restart problems.
Verify that the switch’s pressure range, wetted materials, seals, and temperature limits are suitable for the refrigerant and lubricant used in the system. Also check the required pressure connection and reset behavior. Do not assume a switch is compatible with every refrigerant simply because it is intended for refrigeration applications.
Frequent cycling may be caused by system leaks, an undersized pressure tank, incorrect tank air charge, or a pressure differential that is too narrow for the application. Check for pressure loss and unstable system pressure before adjusting the switch. If the problem persists, verify that the cut-in, cut-out, and differential settings are appropriate for the equipment.