    Air Pressure Switch, 0.2–65 Bar, NO/NC

    SKU: SUCH-APS-LF08
    $62.92
    ● Pressure range 0.2–65 bar ● Contact type NO/NC ● Protection rating IP67 ● Mechanical life 100,000 cycles
    *
    *
    *
    *
    🚚 Free shipping
    🕒 Delivery date: 6-12 days
    🔁 30-day Returns
    Overview

    The SUCH air pressure switch monitors pressure and switches an electrical circuit when the preset pressure is reached. It covers preset pressure settings from 0.2 to 65 bar and offers normally open (NO) or normally closed (NC) contacts. With an IP67-rated housing and pressure-dependent temperature ratings, it is suitable for air compressors, refrigeration systems, pumps, and other equipment using air, water, oil, or compatible refrigerants.

    Feature

    • Wide Pressure Range – Handles preset pressure settings between 0.2 and 65 bar for different pressure control requirements.
    • NO/NC Contact Options – Supports normally open or normally closed switching to suit different control circuit designs.
    • AC/DC Electrical Ratings – Supports specified AC and DC loads for integration with equipment control circuits.
    • Temperature Compatibility – Operates at ambient temperatures from −40°C to 65°C in low-pressure configurations and up to 120°C in high-pressure configurations.
    • IP67 Protection – Resists dust ingress and temporary immersion under specified test conditions for use in demanding industrial environments.
    • Long Switching Life – Provides a mechanical life of 100,000 cycles and an electrical life of 30,000 cycles under specified UL/CE conditions to help reduce replacement frequency.

    Dimension (Unit:mm)

    Air pressure switch dimensions

    Specs
    Pressure Setting Range (Gauge Pressure) 0.02–6.5 MPa; Low pressure: below 1.0 MPa; High pressure: above 1.0 MPa
    Operating Pressure Range (Gauge Pressure) Operating Pressure Value Tolerance Maximum Withstand Pressure
    0.02–<0.6 MPa ±0.03 MPa 1.5 MPa
    0.6–<1.0 MPa ±0.05 MPa 2.0 MPa
    1.0–<2.0 MPa ±0.07 MPa 3.0 MPa
    2.0–<3.0 MPa ±0.10 MPa 4.0 MPa
    3.0–<4.0 MPa ±0.15 MPa 5.5 MPa
    4.0–<5.0 MPa ±0.20 MPa 6.5 MPa
    5.0–<6.5 MPa ±0.25 MPa 8.0 MPa
    Burst Pressure (Gauge Pressure) 34.5 MPa for 1 minute, with no damage or leakage
    Operating Temperature Ambient Temperature Medium Temperature
    Operating Temperature Low pressure: −40 to 65°C; High pressure: −40 to 120°C Low pressure: −40 to 80°C; High pressure: −40 to 135°C
    Electrical Rating 24–250 VAC, 0.02–6 A; 8–36 VDC, 0.02–3 A; 600 VAC, 0.02–3 A (UL)
    Electrical Rating 120 VAC, 6 A; 250 VAC, 6 A (CE)
    Maximum Current (No-Differential-Pressure Version) 0.5 A to ensure electrical life
    Compatible Media Air, water, oil, lubricants, refrigerants, and similar hydrocarbons
    Ingress Protection Rating IP67
    Mechanical Life 100,000 cycles
    Electrical Life 30,000 cycles (UL, CE)
    Certifications UL, CE
    Application
    Air pressure switch for air compressors

    Air Compressors

    Air pressure switch for refrigeration systems

    Refrigeration Systems

    Air pressure switch for water pumps

    Water Pumps

    FAQ
    ❯

    Choose a switch that matches the compressor’s cut-in and cut-out pressures, control circuit, and electrical load. Check whether the switch needs to control the motor directly or operate through a contactor or motor starter. Also consider the compressor’s unloading arrangement to help prevent excessive starting current or repeated restart problems.

    ❯

    Verify that the switch’s pressure range, wetted materials, seals, and temperature limits are suitable for the refrigerant and lubricant used in the system. Also check the required pressure connection and reset behavior. Do not assume a switch is compatible with every refrigerant simply because it is intended for refrigeration applications.

    ❯

    Frequent cycling may be caused by system leaks, an undersized pressure tank, incorrect tank air charge, or a pressure differential that is too narrow for the application. Check for pressure loss and unstable system pressure before adjusting the switch. If the problem persists, verify that the cut-in, cut-out, and differential settings are appropriate for the equipment.