All Categories
    Menu Close
    Find a Sensor A - Z

    Ultrasonic Presence Sensor, 28-450cm, PWM/UART

    SKU: SUCH-US-A10
    $90.62
    ● Output UART / PWM / Switching ● Operating voltage 3.3–5.25 V DC ● Low power <10 µA / <10 mA ● Human detection 28–450 cm
    *
    🚚 Free shipping
    🕒 Delivery date: 6-12 days
    🔁 30-day Returns
    Overview

    This ultrasonic presence sensor operates on 3.3–5.0 V DC with UART Auto/Controlled, PWM Auto/Controlled, and switching outputs. It detects humans over 28–450 cm with a 0–28 cm blind zone, ±(1+S×0.3%) cm temperature-compensated accuracy, <10 µA quiescent current, and <10 mA operating current. With ESD protection and -15–60°C operation, it suits smart automation, presence detection, and human sensing.

    Feature

    • Ultra-Low Power Design: 3.3–5.0 V DC, <10 µA quiescent, <10 mA operating.
    • Flexible Output Modes: UART Auto, UART Controlled, PWM Auto, PWM Controlled, Switching.
    • Fast Presence Detection: ≤37 ms operating duration, 28–450 cm range, 0–28 cm blind zone.
    • High Accuracy with Compensation: ±(1+S×0.3%) cm accuracy with built-in temperature compensation.
    • Robust ESD & Climate Tolerance: ±4 kV/±8 kV ESD, –15 to +60 °C, ≤80% RH.

    Dimension

    Ultrasonic presence sensor dimensions drawing.

    Wiring

    Ultrasonic presence sensor wiring diagram.

    Pin No. Color Mark Description Remark
    1 Red VCC 3.3–5 V power input /
    2 Black GND Ground /
    3 Yellow RX Functional pin Mode-dependent
    4 White TX Functional pin Mode-dependent
    Spec
    Output Mode UART Auto / UART Controlled / PWM Auto / PWM Controlled / Switching (optional)
    Operating Voltage 3.3 to 5.0 V DC
    Operating Voltage Range 3.3 to 5.25 V
    Typical Operating Voltage 5.0 V
    Quiescent Current <10 µA
    Operating Current <10 mA
    Peak Current Range 25 to 50 mA
    Peak Input Ripple Range ≤50 mV
    Peak  Input Noise Range ≤100 mV 
    ESD Range Level 1 ±200 V / ±2 kV
    ESD Range Level 2 ±4 kV / ±8 kV
    Operating Duration Time ≤37 ms
    Measuring Range 28 to 450 cm (human detection)
    Blind Zone 0 to 28 cm (human detection)
    Accuracy  ±(1+S×0.3%) cm (human detection)
    Temperature Compensation Supported
    Operating Temperature Range -15 to 60 °C
    Typical Operating Temperature 25 °C
    Operating Humidity Range ≤80% RH
    Typical Operating Humidity 65% RH
    Storage Temperature Range -25 to 75 °C
    Typical Storage Temperature 25 °C
    Storage Humidity Range ≤90% RH
    Typical Storage Humidity 65% RH

    Note:

    • Typical data: approx. 25°C, 65% RH, 5V, 100ms duty cycle.
    • Approx. 25°C, 65% RH; target: 50×60 cm flat carton; transducer perpendicular to target.
    • ESD ±200 V / ±2 kV.
    • ESD ±4 kV / ±8 kV.
    • 0 to 39°C, max. 90% RH (non-condensing).
    • 40 to 50°C: max. RH = highest natural RH at current temp.
    Application
    Ultrasonic presence sensor detecting occupancy at an office workstation for smart energy saving and lighting control.

    Office Occupancy

    Ultrasonic presence sensor monitoring meeting room occupancy for smart building automation and HVAC control.

    Meeting Room Occupancy

    Ultrasonic presence sensor monitoring locker access and queue management in a commercial smart facility.

    Queue Detection

    FAQ
    ❯

    A: This ultrasonic presence sensor operates on 3.3 to 5.0 V DC, with an absolute range of 3.3 to 5.25 V and a typical voltage of 5.0 V. Its quiescent current is <10 µA, operating current is <10 mA, and peak current can reach 25 to 50 mA. Peak input ripple should stay ≤50 mV, and peak input noise should stay ≤100 mV for stable operation.

    ❯

    A: This ultrasonic presence sensor is designed for human detection with a range of 28 to 450 cm and a blind zone of 0 to 28 cm. That means reliable human presence detection starts beyond 28 cm. For best performance, keep the person or target outside the 28 cm blind zone and within 450 cm.

    ❯

    A: Yes. This ultrasonic presence sensor operates from -15 to 60 °C, with a typical operating temperature of 25 °C, and supports up to ≤80% RH operating humidity (typical 65% RH). Storage range is -25 to 75 °C with ≤90% RH. The notes also specify that at 0–39 °C, max RH is 90% non-condensing; at 40–50 °C, the max RH follows the highest natural RH at the current temperature.

    0.0 0
    Write your own review Close
    *
    *