You have no items in your shopping cart.
Good price vinyl chloride gas sensor for industrial use, featuring flexible detection ranges of 0-20ppm/0-100ppm, resolution of 0.5ppm, and sensitivity of 450±200 nA/ppm. Utilizes an electrochemical three-electrode principle for continuous operation even in non-condensing environments.
Vinyl chloride sensors typically employ electrochemical or infrared principles. Electrochemical sensors detect gas concentration by generating a current signal proportional to the concentration through redox reactions of vinyl chloride molecules on the electrode surface. Infrared sensors measure based on vinyl chloride's absorption characteristics of specific infrared wavelengths.
Chlorine gas sensors are widely used in production, transportation, and application sites involving chlorine. Examples include chlor-alkali plants, drinking water and wastewater treatment facilities, bleach manufacturing, the paper industry, and laboratory environments. By continuously monitoring chlorine levels, sensors help personnel promptly detect leakage risks, preventing personnel poisoning or equipment corrosion.
Avoid prolonged exposure to high concentrations of vinyl chloride during sensor operation, as this may impair electrode performance and shorten sensor lifespan. Regular calibration is recommended to maintain detection accuracy. Select models with appropriate protection ratings based on the operating environment. During installation, ensure the gas sensor is positioned in an area with adequate airflow, avoiding blind spots and stagnant zones.