All Categories
    Menu Close
    Find a Sensor A - Z

    Hydrogen Chloride (HCl) Gas Sensor, 0-50ppm, 0-500ppm

    SKU: SUCH-GAS-HCl
    $148.82
    ● Detect: Hydrogen Chloride (HCl) ● Rang: 0-50ppm, 0-500ppm ● Electrochemical three-electrode ● Resolution: 0.1ppm
    *
    🚚 Free shipping
    🕒 Delivery date: 6-12 days
    🔁 30-day Returns
    Overview

    Precision and durable hydrogen chloride (HCl) gas sensor with 300 ±100 nA/ppm sensitivity for heightened detection acuity. Employing an electrochemical three-electrode principle, it precisely measures HCl concentrations across ranges of 0–50 ppm and 0–500 ppm, with resolution as fine as 0.1 ppm. This ensures rapid response to even the smallest leaks.

    Feature

    HCL gas sensor feature

    • High sensitivity with 0.1 ppm resolution for precise detection of low-concentration hydrogen chloride.
    • Dual range selection (0~50 ppm/0~500 ppm) to meet diverse application requirements.
    • Rapid response ≤70 seconds for real-time detection of hazardous gas leaks.
    • Stable and durable with a 2-year lifespan, low maintenance costs, and long-term reliable protection.

    Dimension (unit: mm)

    HCL gas sensor dimension

    Circuit Diagram

    HCL gas sensor circuit diagram

    Cross Interference

    Interference Gas Gas Concentration Used (ppm) Displayed Value (ppm HCl)
    CO 100 -1
    H₂S 25 110
    H₂ 1000 -18
    NO 50 140
    NO₂ 20 -1
    SO₂ 25 15


    Response Recovery Curve

    HCL gas sensor response recovery curve

    Temperature Dependency Curve

    HCL gas sensor tempe dependence curve

    Specs

    Range Select

    Detection Range 0-50ppm 0-500ppm
    Maximum Load Concentration 200ppm 1000ppm
    Sensitivity 300 ±100 nA/ppm 80 ±30 nA/ppm
    Resolution 0.1ppm 2ppm


    Universal Specs

    Detection Principle Electrochemical three-electrode
    Detected Gas Hydrogen Chloride (HCl)
    Detection Range 0~50 ppm, 0-500ppm
    Maximum Load Concentration 100 ppm
    Sensitivity 300 ±100 nA/ppm
    Zero Drift 0~5 ppm
    Resolution 0.1 ppm
    Precision ±10%
    Response Time ≤70s
    Operating Pressure 90 to 110 kPa
    Temperature Range -30°C to 50°C
    Humidity Range 15%RH to 90%RH (Non-condensing)
    Repeatability < ±2% signal/month
    Long-term Stability < 2% signal/month
    Linearity Linear
    Service Life 2 years
    Application
    Hydrogen chloride detector

    Hydrogen Chloride Detector

    Industrial hcl gas detection

    Industrial HCL Gas Detection

    Livestock chloride detection

    Livestock Chloride Detection

    FAQ

    Hydrochloric chloride (HCl) gas sensors are primarily used for real-time monitoring of HCl concentrations in the air. Hydrochloric acid is a highly corrosive and toxic gas. Leaks can harm the human respiratory system and corrode equipment.

    Most HCl sensors utilize electrochemical detection principles. This method offers high sensitivity, excellent selectivity, and rapid response, enabling accurate HCl detection at the ppm level. Some high-end devices also incorporate optical or infrared technology to enhance long-term stability and interference resistance.

    Hydrogen chloride sensors are commonly used in chemical production, metallurgical smelting, pharmaceutical plants, laboratories, and facilities involving HCl storage and transportation.

    0.0 0